Blog Detail

Maintenance-free Lead – Acid battery for emergency UPS,lighting, power tools

24 Nov 16
ecercom
No Comments

Maintenance-free Lead – Acid battery for emergency UPS,lighting, power tools

 

Thre are usually 2 types battery for UPS battery , AGM and GEL .

AGM batteries indicate Valve Regulated Lead Acid Batteries with the following features: Maintenance-free, no water adding required; sealed valve-regulated, spill proof and leak proof; using unilateralism exhaust (safe vent valve) design on the battery cover, when the battery internal pressure have been up to the specifically value, the safe vent valve will open automatically, and will close after the pressure has been discharged, which can prevent the air to enter into battery.

General Featuress

  1. Silver-coated copper terminals (T1, T2 terminal), brass insert terminals and lead terminals improvethe electric conductivity
  2. Thin plate technology, special grid design, unique paste formula and plate curing process optimize high rate performance
  3. High quality AGM separators with less electrical resistance improve high current discharging properties
  4. ABS material: increase the strength of battery container (Flame-retardant ABS is optional)

Typical Applications

1.UPS (High rate) 2.High power backup supply 3.Emergency power supply
4.Starting system 5.Power tools 6.Emergency lighting 7.Electric starting

Curve Picture

Specifications

Model Nominal Rated Capacity(AH) Approx Dimension Approx
Weight
Terminal type
Voltage 15min (W/cell) 10HR 5HR 1HR Length Width Height Total Height
(V) 1.60 1.80 1.75 1.60 mm in. mm in. mm in. mm in. kg lbs
V/cell V/cell V/cell V/cell
LPX12-2.2 12 7.65 2.2 1.93 1.72 178 7.01 35 1.38 60 2.36 66 2.6 0.96 2.12 T1
LPX12-3.2 12 11.8 3.2 2.91 2.47 134 5.28 67 2.64 60.5 2.38 66.5 2.62 1.35 2.98 T1/T2
LPX12-5.4 12 20.4 5.4 4.85 4.39 90 3.54 70 2.76 101 3.98 107 4.21 1.74 3.84 T1/T2
LPX12-6.0 12 22.3 6 5.4 4.54 151 5.94 65 2.56 93.5 3.19 99 3.9 2.18 4.81 T1/T2
LPX12-6.5 12 25.3 6.5 5.65 4.52 151 5.94 51 2.01 93 3.66 98 3.86 1.9 4.19 T1/T2
LPX12-7.0 12 28.4 7 6.4 5.91 151 5.94 65 2.56 93.5 3.19 99 3.9 2.5 5.51 T1/T2
LPX12-7.6 12 32.2 7.6 6.95 6.28 151 5.94 65 2.56 93.5 3.19 99 3.9 2.45 5.4 T1/T2
LPX12-12 12 49.8 12 10.5 8.77 151 5.94 98 3.86 95 3.74 101 3.98 4.2 9.26 T1/T2
LPX12-17 12 72.5 17 15.7 14.2 181.5 7.15 77 3.03 167.5 6.59 167.5 6.59 5.78 12.7 T3
LPX12-18 12 78.4 18 16.2 14.8 181.5 7.15 77 3.03 167.5 6.59 167.5 6.59 6 13.2 T3/T12
LPX12-20 12 82.7 20 18.5 16.7 181.5 7.15 77 3.03 166.5 6.56 166.5 6.56 6.9 15.2 12V20N(T12)
LPX12-24 12 99.8 24 21.8 19.7 166.5 6.56 175 6.89 125 4.92 125 4.92 8.8 19.4 T3/T12
LPX12-35 12 137.5 33.3 30.7 24.7 195 7.68 130 5.12 164 6.46 180 7.09 10.5 23.2 T10
LPX12-38 12 126.3 36.6 32.8 25.3 197 7.76 165 6.5 170 6.69 170 6.69 13.2 29.1 T6/T10
LPX12-65 12 230.4 65 55 45.2 348 13.7 167 6.57 178 7.01 178 7.01 21.3 47 T6
LPX12-72 12 237.7 72 60 46.4 259 10.2 168 6.61 208 8.19 214 8.43 22.3 49.2 T6/T9
LPX12-100 12 356.1 100 89 78 330 13 173 6.81 212 8.35 220 8.66 30.4 67 T11
LPX12-120 12 483.8 120 107.2 94.6 410 16.1 177 6.97 225 8.86 225 8.86 37.6 82.9 T11
LPX12-150 12 487.5 150 131 101.3 485 19.1 170 6.69 240 9.45 240 9.45 43.5 95.9 T11
LPX12-200 12 675.8 200 173.5 149.6 522 20.6 240 9.45 218 8.58 224 8.82 62.5 137.8 T11
LPX12-250 12 783.3 250.4 217 193.2 522 20.6 268 10.6 220 8.66 226 8.9 73 161 T11
LPX6-100 6 356.1 100 89 78 195 7.68 170 6.69 206.5 8.13 212.5 8.37 15.6 34.4 T6
LPX6-150 6 487.5 150 131 101.3 260 10.2 180 7.09 247 9.72 253 9.96 21.2 46.7 T7
LPX6-200 6 675.8 200 173.5 149.6 322 12.7 178 7.01 228 8.98 234 9.21 30.5 67.3 T11

Leave A Comment